Select Page

Aeroduct® SCAT Ducting

Recommended for use in conducting extremely cold or hot air, SCAT Ducting can withstand temperatures ranging from -65°F to +550°F. It is lightweight, extremely flexible and features a construction that minimizes waste, as its short sections, which are usually unusable, can be joined together to form a continuous length.

Technical Overview

Inside Diameter (inches)* 2 3 4 5 6
Weight (pounds per foot) .19 .29 .38 .48 .58
Inside Bend Radius (inches) .50 .75 1.0 1.25 1.50
Length Required for 180º Bend (inches) 8 12 16 20 24
Minimum Burst Pressure (psig) 102 88 69 57 41
Internal Working Pressure (psig) 25 22 17 14 10
Maximum Leakage (ctm/ft. at working pressure) .010 .015 .020 .025 .030
Crush Resistance (pounds per foot) 400 320 290 240 200
Axial Tensile Strength (pounds) 375 535 660 870 900
Retracted Length (inches per foot) 3.5 3.5 2.5 2.1 2.0
Operating Temperature Range -65ºF to +550ºF

Literature

Thermoid Aviation Ducting and Hose Products – Brochure

Features & Benefits

cyclone-scat

A. Support
  • Copper-coated or bronze-plated spring steel-wire helix
B. Cover
  • Woven fiberglass fabric infused with silicone rubber. Standard length – 11 ft.
C. Cord
  • Fiberglass cord coated with silicone
Applications
  • For use in conducting extremely cold or hot air where temperatures. Not recommended for negative pressure applications

More